1. Specific Needs & Cold Storage Demands in Tuyen Quang
Tuyen Quang has the succulent Ham Yen orange brand and the Shan Tuyet Na Hang specialty tea area, which needs chilled storage for post-harvest to avoid bruising.
2. Key Industrial Parks & Strategic Logistics Zones Served in Tuyen Quang
Tan Long engineering teams have deployed cold storage facilities, blast freezers, and cleanrooms across major industrial zones in Tuyen Quang:
Long Binh An Industrial Park (Tuyen Quang City)
Forest product and tea processing center and agricultural warehouse.
3. Latest 2026 Cold Storage Installation Pricing in Tuyen Quang
The pricing below represents a comprehensive turnkey estimate including: Insulated sandwich panels (PIR/PU), imported compressor rack, air coolers, PLC automation cabinet, doors, and on-site turnkey installation in Tuyen Quang:
| Volume (m³) | Dimensions L x W x H (m) | Chilled Store (+2°C to +10°C) | Frozen Store (-18°C to -25°C) | Recommended Compressor Rack |
|---|---|---|---|---|
| 20 m³ | 3.0 x 2.5 x 2.7m | 68.000.000 VND - 78.000.000 VND | 85.000.000 VND - 98.000.000 VND | Copeland / Bitzer 3.0 HP |
| 50 m³ | 5.0 x 4.0 x 2.5m | 115.000.000 VND - 130.000.000 VND | 145.000.000 VND - 165.000.000 VND | Bitzer Piston 5.0 HP |
| 100 m³ | 8.0 x 5.0 x 2.5m | 180.000.000 VND - 210.000.000 VND | 230.000.000 VND - 260.000.000 VND | Bitzer / Hanbell 7.5 HP |
| 200 m³ | 10.0 x 6.5 x 3.0m | 290.000.000 VND - 330.000.000 VND | 380.000.000 VND - 430.000.000 VND | Bitzer Screw 15 HP |
| 500 m³ and above | Per Actual Jobsite Layout | Custom Engineering Proposal | Custom Engineering Proposal | Mycom / Kobelco Screw |
* Note: Actual turnkey quotation may vary depending on refrigerant piping distance, local fire protection standards, and 3-phase electrical connections at the Tuyen Quang jobsite. Contact hotline (+84) 933 357 058 for an itemized estimate within 15 minutes.
Cold Storage Heat Load Sizing & Pricing Calculator for Tuyen Quang
Calculate required kW/HP cooling capacity, panel insulation thickness, and estimated turnkey project investment in 30 seconds.
4. Featured Regional Projects Executed by Tan Long
Chilled Storage for Cam Sanh Ham Yen
Ham Yen, Tuyen Quang DistrictTechnical Configuration: Scale 1,500m³, temperature +6°C to +8°C, humidity 88% keeps oranges fresh for 2 months.
5. 6-Phase Turnkey Cold Storage Construction Protocol by Tan Long in Tuyen Quang
1. Complimentary On-Site Jobsite Survey
Tan Long certified refrigeration engineers conduct on-site dimension surveys, verify electrical transformer capacity, and optimize layout.
2. 3D Thermodynamic Modeling & BOQ
Generating detailed 2D/3D BIM drawings, calculating precise kW thermal loads, and providing transparent itemized BOQ.
3. Off-Site Factory Prefabrication
Manufacturing PIR/PU panels and assembling compressor racks at Duc Hoa 1 plant under strict ISO 9001:2015 quality control.
4. Structural Enclosure & Mechanical Installation
Certified mechanical teams erect Camlock panels with airtight joints, lay copper/steel piping, and mount evaporator units.
5. Nitrogen Pressure Testing & Deep Evacuation
Three-stage nitrogen pressure testing per DIN EN 378 and deep vacuuming (< 500 microns) before refrigerant charging.
6. 72-Hour Commissioning, Acceptance & Handover
Continuous 72-hour temperature pull-down testing, complete technical documentation handover, and staff training.
6. Technical FAQs on Cold Storage Installation in Tuyen Quang
Q: Will Ham Yen oranges turn sour if stored cold?
No. Humidity control above 85% keeps orange cloves succulent and not mushy.
Q: What is Tan Long's warranty and emergency technical response policy in Tuyen Quang?
All cold storage facilities constructed in Tuyen Quang receive a 24-month comprehensive manufacturer warranty on compressor machinery and 5 years on insulated panels. Our 24/7/365 regional emergency team guarantees rapid on-site arrival.
Q: Can a cold storage unit be installed in Tuyen Quang if the jobsite does not have a 3-phase power supply?
For compact cold rooms under 20m³, Tan Long offers compressor configurations compatible with single-phase 220V residential power. However, for cold storage facilities of 30m³ and above, a 3-phase 380V power supply is required for compressor durability and energy efficiency. Tan Long engineers will provide electrical load calculations and engineering submittals to assist in rapid utility grid application.