TÂN LONG
Industrial Water Chiller System

Industrial Water Chiller Unit

Tan Long industrial water chiller systems deliver continuous chilled water circulation (+5°C to +15°C) for cleanroom HVAC, plastic injection mold cooling, breweries, dairy processing, and chemical reactor vessels. Incorporating inverter-driven screw compressors cuts power consumption by up to 30%.

Industrial Water Chiller Unit: Industrial water chillers by Tan Long deliver central chilled water for factory HVAC and production machinery cooling. High-grade SUS304 shell-and-tube evaporators paired with PLC touch controllers maintain water delivery temperatures within a tight ±0.5°C margin.
Across modern processing plants, a reliable source of chilled process water (+1°C to +7°C) is essential for food processing, chemical cooling, and HVAC cleanrooms. Tan Long packages flooded and falling-film chillers delivering unmatched energy efficiency. Water Chiller Tan Long is engineered to heavy industrial standards with durable copper or stainless shell-and-tube evaporators, intelligent anti-freeze microprocessors, and automated load balancing.
Máy Làm Lạnh Nước Water Chiller: Giải Pháp Nước Lạnh Trung Tâm Hiệu Suất Cao
Water-cooled dual screw compressor water chiller installed by Tan Long at KIDO food processing plant

Tan Long Factory Standard Technical Specifications Matrix

Cooling Capacity Range 50 HP to 1,000 HP (150 kW to 3,500 kW)
Standard Leaving Water Temp +5°C to +12°C (or sub-zero -5°C with Glycol brine)
Condenser Cooling Type Water-Cooled or Air-Cooled
Integrated Compressor Type Semi-hermetic screw compressors Bitzer / Hanbell / Danfoss
Evaporator Type High-efficiency horizontal shell-and-tube or Alfa Laval plate heat exchanger
Condenser Type Shell-and-tube with copper tubes cooled via cooling tower
Refrigerants Eco-friendly R134a, R407C, R410A
Control System Multilingual PLC touchscreen HMI, interfacing with SCADA/BMS
Get 2026 Equipment Quotation Download Technical Catalog (PDF)

1. Water-Cooled Configuration Optimized for Tropical Climates

In tropical zones where summer ambient reaches 38°C - 40°C, Tan Long engineers water-cooled chillers paired with cooling towers:

• Condensing temperature is maintained at a modest 35°C - 37°C, easing compressor pressure ratios.

• COP energy efficiency reaches 4.8 to 5.5, saving hundreds of millions of VND annually for 3-shift facilities.

2. Multi-Tier Anti-Freeze Tube Burst Protection

Water freezing inside shell-and-tube evaporators is a critical chiller hazard. Tan Long integrates 4 independent safeguards:

1. Electronic flow switch tripping compressors immediately if water flow decreases.

2. Antifreeze thermostat cutting out if water drops below +3°C.

3. Low-pressure transducer monitoring instantaneous suction pressure.

4. Micro-stepping electronic expansion valve (EEV) algorithm responding in milliseconds.

3. Industrial Applications Across Manufacturing Facilities

Tan Long industrial water chillers operate across leading facilities:

• KIDO Foods Cu Chi: Glycol chiller (-10°C) powering continuous ice cream manufacturing lines.

• Pharmaceutical cleanrooms and semiconductor plants requiring tight temperature and humidity control under GMP-WHO.

Competitive Advantages & Market Comparison Matrix

Technical comparison between genuine Tan Long refrigeration equipment manufactured at Duc Hoa 1 Industrial Park versus substandard market alternatives:

Tan Long Equipment Advantages

  • ✓ Utilizes VFD inverters to maintain chilled water temperature fluctuations within ±0.5°C
  • ✓ Shell-and-tube evaporators are easily cleaned mechanically, eliminating clogging risks seen in compact brazed plate chillers
  • ✓ 40% lower operating and maintenance costs compared to imported Trane, Carrier, or Daikin chillers
  • ✓ 24/7 on-site technical support with genuine compressor and EEV spare parts immediately available

Drawbacks of Manual / Used Imported Systems

  • ✗ Imported packaged chillers carry high price tags with 2 - 3 month lead times for replacement controller boards
  • ✗ Low-budget uncertified chillers foul rapidly, causing steep drops in cooling capacity
  • ✗ Inadequate antifreeze protection leads to tube freeze-bursts and water flooding into refrigeration circuits
  • ✗ Proprietary locked control systems that cannot interface with factory-wide SCADA platforms

Frequently Asked Questions (FAQs) by Engineers & Investors

Q1: When to choose water-cooled chillers versus air-cooled chillers?

If the facility has adequate rooftop or yard space and water supply, water-cooled chillers are the premier choice, offering 25% lower power consumption and longer equipment life. If water is constrained or space is limited, air-cooled chillers eliminate cooling towers and condenser water piping.

Q2: What is the delivery and installation lead time for Tan Long chillers?

For standard 50 - 200 HP skids, Tan Long maintains factory stock ready for delivery and installation in 7 - 10 days. Customized high-capacity chillers are delivered within 25 - 35 business days.

TURNKEY AUTOMATION, PRESSURE VESSELS & EPC SIZING

SCADA IoT remote temperature monitoring and ASME certified pressure vessels engineered for zero downtime:

TECHNICAL EXPERT VERIFICATION

Updated: September 2026 • Standards: TCVN 6739 & QCVN 06:2022
Eng. Nguyen Van Long - EPC Technical Director
EXPERT AUTHOR

Eng. Nguyen Van Long

EPC Technical Director & Head of Refrigeration Solutions, Tan Long

20+ years EPC experience in industrial cold storage systems, IQF quick freezers, and automated ASRS facilities. Thermal Engineering alumnus from HCMC University of Technology, VISRAE Executive Board member.

M.Sc. Tran Dinh Hung - Pressure Safety Lead, Tan Long
TECHNICAL VERIFICATION

M.Sc. Tran Dinh Hung

Pressure Vessel Safety Verification & Energy Auditing Lead

15+ years leading NH3 piping pressure safety proofing, COP energy audits, and fire protection certification for PIR/PU panel enclosures under QCVN 06:2022/BXD.